Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope

Email to a Friend Share/Bookmark

Availability: In stock

$356.00
Add Items to Cart
OR

Quick Overview

The Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope is follows the GB4793 electronic surveying instrument safely requirements and the IEC61010-1 safely standard to design and produce.

How about FREE SHIPPING ON ORDERS OVER $299 ?

Item ships within 1 to 2 days. We ship to most Countrys. 

Learn more about Locations & Shipping.

Shipping time:Usually 6 to 10 Working Days. 

Learn more about Shipping & Delivery.

Satisfaction GuaranteedLearn more about Return Policy.

Any Questions? Click Buttom of webpage online chat Widget  for More Support or Find more at Customer Service.

 

Product Description

The Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope is a professional tester and with multi-functions, 2 Channels 60MHz with 64k Full colour LCD Display. Our products have been exported to more than 40 countries over the world.

Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope

Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope

Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope

Uni-T UT2062CE 60MHz 1024K 1GSa / S Digital Oscilloscope

Additional Information

Main Features
  • Double analog channel
  • High clear colored/monochromatic liquid crystal display system, 320×240 resolution
  • Plug and play support USB storage device, and can communication with computer through USB memory device
  • Automatic wave form and condition setup
  • Wave form, setup and the bitmap store as well as the wave form and the setup reappear
  • Fine Windows extended function, precisely analyzes the wave form detail and general picture
  • Automatic measurement 28 kinds of waveform parameter
  • Automatic cursor track measuring function
  • Unique wave form record and playback function
  • Embed FFT 
  • Many kinds of wave form mathematics operation function (including: add, subtract, multiply, divide)
  • Edge, video, pulse width, alternately trigger function
  • Multi-country language menu demonstrated
  • Chinese and English help information demonstrates
  •  
  • Specifications

    Brand

     

    Uni-T

    Model

    UT2062CE

    Bandwidth

    60MHz_chromatic

    Sampling methods

    Real-time sampling

    1.0GS/s

    Equivalent Sampling

    25GS/s

    Average

    2 n-th power,2 to 256 times optional.

    Enter

    Input Coupling

    DC _ AC input coupling, ground (DC, AC, GND)

    Input impedance

    1 ± 2% ΜΩ, and 24 ± 3pF parallel

    probe attenuation coefficient Setting

    1X, 10X, 100X, 1000X

    Maximum input voltage

    400V (DC + AC peak, 1ΜΩ input impedance) (10:1 probe attenuation)

    Channel isolation

    better than 40:1

    Time delay between channels (typical)

    150ps

    Level

    Waveform interpolation

    sin(x)/x

    Recording and storage

    memory depth: 1M samples

    Scan range_S/div_

    5ns/div _ 50s/div,1-2-5 band (60MHz\80MHz\100MHz)

    Sampling rate and delay time accuracy

    ± 100ppm (any time interval ≥ 1ms)

    Time interval (_ T)
    Measurement accuracy (full bandwidth)

    Single: ± (1 sampling interval +100 ppm × reading +0.6 ns)> 16 Four Means: ± (1 sampling interval +100 ppm × reading +0.4 ns)

    Vertical

    Analog-digital converter (A / D)

    8-bit resolution, two-channel simultaneous sampling

    Deflection coefficient

    2mV/div _5V/div(at input BNC Office)

    Displacement range

    ±10div

    analog bandwidth

    60MHz

    Optional analog bandwidth limitations, typical

    20MHz

    Low frequency response (AC-coupled,-3dB)

    ≤ 10Hz (in the BNC on)

    Rise time (in the BNC on typical)

    _5.8ns

    DC gain accuracy

    2mv/div, 5mv/div hours ± 4% (average sampling or sampling method)

    10mv/div ~ 5v/div Time: ± 3% (average sampling or sampling method)

    DC measurement accuracy (average sampling mode)

    vertical displacement is zero, and N ≥ 16 _: ± (4% × reading +0.1 div +1 mV); vertical deflection coefficient ≥ 5mV/div; N ≥ 16 _: ± [ 3% × (reading + vertical displacement of the reading) + (1% × vertical displacement of the reading)] +0.2 div) vertical deflection coefficient increases from 2mV/div to 200mV/div 2mV; vertical deflection coefficient 500mV/div to 5V/div plus 50mV .

    Voltage difference (ΔV) measurement accuracy (average sample method)

    in the same settings and environmental conditions, through to the capture of ≥ 16 waveforms averaged waveform office after the voltage difference between two points (ΔV): ± (3% × reading +0.05 div)

    Trigger

    Trigger sensitivity

    DC ~ 10MHz 0.5div 10MHz ~ limit the bandwidth 1div

    Trigger level range

    internal

    from the screen center within ± 10div

    EXT

    ±1.6V

    EXT/5

    ±8V

    Trigger level accuracy (typical) accuracy for the rise and fall times ≥ 20ns signal

    internal

    ± (0.3div × V / div) (from the screen center within ± 4div)

    EXT

    ± (6% setting +40 mV)

    EXT/5

     

    ± (6% setting +200 mV)

    Pre-trigger capability

    normal mode / scan mode, pre-trigger / delay trigger, adjustable pre-trigger depth

    Release inhibiting range

    100ns-1.5s

    Set the level to 50% (typical)

    input signal frequency ≥ 50Hz operation under

    Edge-triggered

    Edge type

    up, down

    Trigger pulse width

    Trigger mode

    (greater than, less than, equal to) is pulse width, (greater than, less than, equal to) the negative pulse width

    Pulse width

    20ns-10s

    Video Trigger

    Trigger sensitivity

    internal

    2div peak value

    (Video trigger, typical)

    EXT

    400mV

     

    EXT/5

    2V

    Signal format and line / field
    Frequency (Video Trigger Type)

    supports standard NTSC and PAL, lines range is 1-525 (NTSC) and 1-625 (PAL)

    Alternate trigger

    CH1 trigger

    edge, pulse width, video

    CH2 trigger

    edge, pulse width, video

    Measure

    Cursor

    manual mode

    voltage difference between cursors (ΔV), the time difference between cursors (ΔT), ΔT the countdown (Hz) (1/ΔT)

    Tracking mode

    Tracking mode voltage waveform point and time value

    Automatic measurement

    peak, amplitude, maximum, minimum, top value, bottom value, average, RMS value, overshoot, pre-washed, frequency, period, rise time, fall time, positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, delay 1 -> 2 (up), delay 1 -> 2 (down) measurement

    Mathematical operations

    add, subtract, multiply, divide, RP

    Storage Wave

    10 waveforms, 10 types of settings

    FFT

    Window

    Hanning,Hamming,Blackman,Rectangular

    Sampling points

    1024 points

    Lissajous Figures

    phase

    ±3 degrees

    Display

    Display Type

    diagonal of 145 mm (5.7 inches) LCD display

    Display resolution (Display)

    ?320 levels × RGB × 240 vertical pixels (color)

    Display Color

    chromatic

    Display contrast

    adjustable

    Backlight intensity (typical)

    300nit

    Display language

    Chinese Simplified, Chinese Traditional, English

    Probe Compensator Output

    Output voltage (typical)

    about 3V, peak - peak load ≥ 1MΩ

    Frequency (typical)

    1kHz

    Interface functions

    Standard

    1 USB (D); 1 _ USB (H); 1 _ RS-232C

    Optional

    GPIB and LAN

    Power supply

    Supply voltage

    100-240VACRMS 45Hz to 440Hz, CAT II

    Power consumption

    less than 30VA

    Fuse

    2A, T stage, 250V

    Environment

    Temperature

    Operating: 0 _ ~ +40 _

    Non-operating: -20 _ ~ +60 _

    cooling

    Convection

    Humidity

    +10 _ ~ +30 _: ≤ 95% ± 5% RH,

    +30 _ ~ +40 _: ≤ 75% ± 5% RH

    high

    3,000 meters operation

    Non-operating 15,000 m

    Non-operating 15,000 m

    Dimensions

    320mm (W) × 150mm (high) × 130mm (D)

    Weight (Net)

    excluding packaging

    2.5kg

    including packaging

    4.0 kg

    IP protection

    IP2X

    Package Including
  • 1 x UTD2062CE Digital Oscillosopes
  • 1 x USB Cable
  • 2 x Probes
  • 1 x Power Cord
  • Product Tags